Balboa-water-group VGB 2008 211 GPM Suction Flow User Manual

Browse online or download User Manual for Accessories for water Balboa-water-group VGB 2008 211 GPM Suction Flow. Balboa Water Group VGB 2008 211 GPM Suction Flow User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
VGB 2008
211 GPM Suction Flow
Installation Instructions
For single or multiple use submerged suction outlet. 1.
Do not try to locate suction outlets on seating areas or on the brackets for such seating areas. 2.
When two or more suction fittings are used on a common suction line they shall be separated by a minimum of 3 ft. (91.44 cm), or, 3.
if any are located closer they shall be located on two different planes (i.e., one each on two separate vertical walls). Confirm with
local and national codes and standards for proper installation.
In the event of one suction outlet being completely blocked, the remaining suction outlets serving that system shall have a flow 4.
rating capable of the full flow of the pump(s) for the specific suction system.
Maximum flow rating with head loss curve: 211 GPM. 5.
Acceptable connecting pipe size(s) - maximum 2.5.6.
Mounting position: wall only 7.
Suction outlet part number 30231 U applicable. 8.
Part numbers: 9.
30231 U VGB 2008 211 GPM SUCTION COVER & SCREW/UV (replace within seven installed years)
30341 VGB 2008 BUTTRESS SUCTION WALL FITTING X CUSTOM SLIP (replace within seven installed years)
30234-V SUCTION L-GASKET USE 3.75” HOLE SIZE (replace within seven installed years)
30236-V SUCTION FLAT GASKET (replace within seven installed years)
30238-V SUCTION COMPENSATING RING (replace within seven installed years)
63414 3/4” ID x 1” OD TUBING 8-FT LONG (replace within seven installed years)
30239-V SUCTION NUT (replace within seven installed years)
30167-V 2”SPG X CUSTOM SPG X 3/4” SMOOTH BARB SAFETY SUCTION ADAPTER (replace within seven installed years)
30169-V 2 1/2”SPG X CUSTOM SPG X 3/4” SMOOTH BARB SAFETY SUCTION ADAPTER (replace within seven installed years)
Tools required: Philips screw driver, glue for plumbing connections, clamp & pliers for tubing connections. 10.
Service and winterizing instructions. 11.
a. Service - remove screw. Remove cover. Place suction cover on wall fitting with blank portion, no holes pointed down.
The keyway on inside cover must match the notch on the wall fitting. Insert stainless steel screw in cover and tighten
securely. Do not overtighten (as plastic will strip).
b. Winterizing - Drain suction line thoroughly and blowout all remaining water. See spa manufacturer instructions
for winterizing.
WARNING: Do not exceed the maximum allowable flow rate stated on the suction fitting. 12.
The suction fitting including fasteners should be observed for damage or tampering before each use of this facility. 13.
Note: Missing, broken, or cracked suction fittings shall be replaced before using this facility. Loose suction fittings shall be reat-
tached or replaced before using this facility. Read, then keep these instructions for future reference.
Caution: Be aware that changing pump types and sizes can increase flow rate. The maximum flow rate is 211 GPM.
Instructions
40747 Rev A May 21, 2012
Page view 0
1 2

Summary of Contents

Page 1 - Instructions

VGB 2008 211 GPM Suction Flow Installation InstructionsFor single or multiple use submerged suction outlet. 1. Do not try to locate suction outlets

Page 2

Step OneDo not locate suction outlets on seating areas or on the brackets for such areas. Step TwoCut a 3.5” hole into the spa wall for a flat gasket.C

Comments to this Manuals