Balboa-water-group VGB 2008 179 GPM Suction Flow User Manual

Browse online or download User Manual for Accessories for water Balboa-water-group VGB 2008 179 GPM Suction Flow. Balboa Water Group VGB 2008 179 GPM Suction Flow User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
179 GPM Suction Flow Installation Instructions
Packaging and Installation Instructions - SAVE INSTRUCTIONS
Instructions
For multiple drain use only in self-contained factory manufactured spas.1.
Do not try to locate suction outlets on seating areas or on the brackets for such seating areas.2.
When two or more suction fittings are used on a common suction line they shall be separated by a minimum of 3 ft. (91.44 cm); 3.
or, if any are located closer they shall be located on two different planes (i.e., one each on two separate vertical walls). Confirm
with local and national codes and standards for proper installation.
In the event of one suction outlet being completely blocked, the remaining suction outlets serving that system shall have a flow 4.
rating capable of the full flow of the pump(s) for the specific suction system.
Maximum flow rating with head loss curve: 179 GPM without vacuum tube.5.
Acceptable connectin6. g pipe size(s) - maximum 2.5” dia.
Mounting position: wall only7.
Suction outlet part number 30240U applicable.8.
Part numbers for 179 GPM configuration: (Replace within seven installed years)9.
30240U-XX VGB 2008 256 / 179 GPM suction cover & Screw/UV
30241 VGB 2008 179 GPM wall fitting x 2”S
30248 VGB 2008 179 GPM wall fitting x 2.5”S
30234-V Suction L gasket use 3.75” hole size
30236-V Suction flat gasket use 3.63” hole
30238-V Compensating ring
30239-V Suction nut
Tools required: Philips screw driver, glue for plumbing connections, clamp & pliers for tubing connections.10.
Service and winterizing instructions. 11.
a. Service - remove screw. Remove cover. Place suction cover on wall fitting with blank portion, no holes pointed down.
The keyway on inside cover must match the notch on the wall fitting. Insert stainless steel screw in cover and tighten
securely. Do not overtighten (as plastic will strip).
b. Winterizing - Drain suction line thoroughly and blow out all remaining water. See spa manufacturer instructions for
winterizing.
WARNING: Do not exceed the maximum allowable flow rate stated on the suction fitting.12.
The suction fitting including fasteners should be observed for damage or tampering before each use of this facility. 13.
Note: The suction fitting including fasteners should be observed for damage or tampering before each use of this facility.
Missing, broken, or cracked suction fittings shall be replaced before using this facility. Loose suction fittings shall be reattached
or replaced before using this facility. Read, then keep these instructions for future reference.
Caution: Be aware that changing pump types and sizes can increase flow rate. The maximum flow rate is 179 GPM
without a vacuum tube.
Patented under U.S. Patent No. 8,191,183.
42138 A May 21, 2012
Page view 0
1 2

Summary of Contents

Page 1 - Instructions

179 GPM Suction Flow Installation InstructionsPackaging and Installation Instructions - SAVE INSTRUCTIONSInstructionsFor multiple drain use only in s

Page 2 - 42138 A May 21, 2012

179 GPM Suction Installation Instructions©2012 Balboa Water Group. All rights reserved. 42138 A May 21, 2012

Comments to this Manuals

No comments