Balboa-water-group 1 Slimline Air Control 10-2330 User Manual

Browse online or download User Manual for Accessories for water Balboa-water-group 1 Slimline Air Control 10-2330. Balboa Water Group 1 Slimline Air Control 10-2330 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 1
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
1” SLIMLINE AIR CONTROL INSTRUCTIONS
10-2310 & 10-2330
The correct hole size for the 1” Slimline Air Control is 1-3/4”.
1. Before drilling a hole for air control make sure surface is flat, so the Slimline Air Control will have the best surface
to seal against.
2. Drill a 1-3/4” hole.
3.
Align window on the handle (#7) with the “MIN” position. Place the palm of the hand against the top of the
Slimline Air Control handle (#7), and press down firmly, rotating the handle counterclockwise about a quarter turn.
4. Grasp the outer edges of the handle with your fingertips and pull the handle from the outer body (#3). Remove check valve
ball (#4) from outer body (#3).
5. Place silicone on backside of flange of outer body (#3) and install through hole in spa/bathtub.
88-2310 Rev C June 16, 2009
6. Place gasket (# 2) onto body on the outside of spa wall.
7. Hand tighten nut (# 1) onto body.
8. Glue 1” pipe in socket of air control.
IMPORTANT: MAKE SURE CHECK VALVE BALL (#4) WAS REMOVED TO AVOID
EXCESS GLUE FROM INTERFERING WITH CHECK VALVE OPERATION.
9. Remove excess silicone from around flange of air control and surface of spa/bathtub.
10. Once glue is dry reinstall check valve ball (#4).
11. Make sure handle/stem assembly (#8) is in the fully closed position by aligning the window on the
inner body (#5) and making sure the foam is not showing. Insert handle/stem assembly (#8) into
outer body (#3) with the window on the handle (#7) in the “MAX” position.
12. Once the handle/stem assembly (#8) is in the outer body (#3), press on the top surface of the
handle (# 7) firmly and rotate the handle clockwise until it stops (approx. 1/4 turn).
13. Check the MAX and MIN position through the window on the top of the handle, and match
with the operation of the jets. If aeration occurs in the “MIN” position, the Slimline Air Control
has been improperly assembled. To correct, press down firmly on the handle and rotate again
clockwise. Recheck the “MAX/MIN” position with the operation of the jets.
**D0 NOT USE ANY TYPE OF PETROLEUM BASED LUBRICANTS ... THEY WILL DAMAGE THE PRODUCT.
#1 10-3706 NUT
#2 10-3705 GASKET
#3 30-2316 SLIMLINE OUTER BODY
#4 30-2315 SLIMLINE CHECK VALVE BALL
#5 30-2313 SLIMLINE INNER BODY
#6 30-2314 SEAL
#7 30-2311 SLIMLINE HANDLE W/ROTOR
#8 10-2319 SLIMLINE STEM ASSEMBLY